Troubleshooting the timeprovider, Using events to troubleshoot, Event codes – Symmetricom EDGE CLOCK 1000 User Manual
Page 167: Table, Table 6-5, Scribed in

097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 167
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Using Events to Troubleshoot
You can provision most events to generate an alarm; alarm levels include Critical
(CR), Major (MJ), Minor (MN), Event, (NA), and Not Reported (NR).
lists
the event ID and the description of events for the IMC, IOC, and IOC Input.
Table 6-5. Event Codes
Event ID
Keyword
Description
AID
TYPE
Default Value/
Keyword
Description of Values
IMC Event Codes
ACCLVL
The user’s system
access level has
changed in the
database
EQPT
SECURITY
(when no users
have been
assigned to the
system)
NONE – User has access to
all commands; no Security
has been assigned
USER – User can access
User-level commands
ADMIN – User can access
Admin-level commands
SECURITY – User can
access all commands
ACO
Audio alarm has been
deactivated
EQPT
N/A
N/A
ALMCHG
The IMC alarm
parameters have
changed
EQPT
N/A
Alarm keywords and values
are listed in
. When
the user changes a value, the
ALMCHG event is generated
and contains the keyword and
value
AOMERGE
Enable/Disable
autonomous event
generation for the
current session
EQPT
ENABLE
ENABLE – Autonomous
messages are displayed in
the current session
DISABLE – Autonomous
messages are not displayed in
the current session
BAUD
The IMC serial port
baud rate has
changed
EQPT
9600
2400 | 9600 | 19200 | 28800 |
38400 | 57600
CMDCHG
The command access
level has changed
EQPT
ACCLVL-USER
NONE | USER | ADMIN |
SECURITY