Symmetricom EDGE CLOCK 1000 User Manual
Page 133

097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 133
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
This command has a default access level of USER.
Normal Response Format
^^^sid^date^time
M^
^^^”
<:condscr>”
;
where * indicates zero or more of the preceding element
Sample Command
RTRV-ALM:::TS1000;
This command causes the TimeProvider to return all current alarms.
Description
ALL (or null)
SYS
IMC
IOCm (m = 1 | 2)
PRS
INPp (p = 1 | 2)
OUTg (g = A | B | C | D)
Access identifiers
Value
Description
Access identifier
aidtype
Access identifier type
EQPT – alarm associated with operation of the system
T1 – alarm associated with inputs or outputs
ntfcncde
Notification code:
MN – Minor alarm
MJ – Major alarm
CR – Critical alarm
condtype
Condition type – keyword associated with the command
srveff
Service affecting indicator
ocrdat
Occurrence date of the alarm
ocrtim
Occurrence time of the alarm
condscr
Optional condition description – text string enclosed in quotation
marks