Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
134 TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Normal Response
TP-SSU 03-10-24 11:22:11
M
TS1000 COMPLD
"SYS,EQPT:MJ,PWRA,NSA,03-10-24 11-22-11:\"POWER A FAILED\""
"SYS,EQPT:MJ,EXPFAIL,SA,03-10-24 11-22-11:\"EXPANSION CONNECTIVITY FAILED\""
"IOC2,EQPT:MJ,CLKFREE,SA,03-10-24 11-25-15:\"CLOCK ENTERED FREE-RUN MODE\""
"INP1,T1:MN,INPLOS,NSA,03-10-24 11-25-16:\"LOS FAULT\""
"INP2,T1:MN,INPDISQ,NSA,03-10-24 11-25-17:\"INPUT DISQUALIFIED AS POSSIBLE
REFERENCE\""
"INP2,T1:MN,INPLOS,NSA,03-10-24 11-25-17:\"LOS FAULT\""
;
Displaying Alarm Status
The RTRV-COND command displays information about the current summary alarm
status of components within the TimeProvider. The active IOC reports alarms for the
Input, Output, and Expansion Panel.
RTRV-COND:[
This command always has an access level of USER.
Normal Response Format
^^^sid^date^time
M ^ctag^COMPLD
^^^”SYS:
^^^”IMC:
[^^^”IOC1:
[^^^”IOC2:
^^^”GPS:
^^^”PRS:
^^^”INP1:
^^^”INP2:
^^^”OUTA:
^^^”OUTB:
^^^”OUTC:
^^^”OUTD:
;
Description
ALL (or null)
Access Identifiers