Clearing alarms – Symmetricom EDGE CLOCK 1000 User Manual
Page 135

097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 135
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Sample Command
RTRV-COND::IOC:TS1000;
Normal Response
TP-SSU 03-10-24 11:27:28
M
TS1000 COMPLD
“SYS,PWRA-OK,PWRB-OK,OK,OK”
;
Clearing Alarms
Clearing the Office (Audible) Alarm
Use the following TL1 command to turn off (squelch) the audible office alarm. The
office alarm reactivates when a new alarm occurs.
OPR-ACO-ALL:[
Description
SYS
Displays the connectivity status of the Expansion Panel and any
alarms associated with the Expansion Panel
IMC
Displays all conditions related to the Information Management module
IOCm
m = 1 | 2
Displays the current setup and conditions related to the system-level
function of the IOC module
IOC2TO1COMM-OK | IOC2TO1COMM-FAIL
IMC2COMM-OK | IMC2COMM-FAIL
GPS
Displays GPS Input state and any alarm events associated with GPS
input
PRS
Displays PRS Input state and any alarm events associated with PRS
input
INPp
p = 1 | 2
Displays Input state and any alarm events associated with Inputs 1 or 2
OUTg
g = 1 | 2 | 3 | 4
Displays output status; this reflects the state of IOCFAIL of the active
IOC