beautypg.com

Sentry Industries 5000 User Manual

Page 92

background image

SMC

sierra monitor corporation

Sentry Instruction Manual - Version 6

APPENDIX A - SPECIFICATIONS

Page: 86

C. PERFORMANCE

Combustible Gas (5100-02)

Range:

0 - 99% Lower Explosive Limit.

Operating Temperature -40

o

F to 158

o

F (-40

o

C to 70

o

C)

Relative Humidity

5 - 99% RH

Accuracy:

+/- 3% of Full Scale or

+/- 10% of Applied Concentration

Response:

Step to 50% within 10 seconds

Recover to 10% within 45 seconds

Calibration Frequency

Monthly, Recommended

Zero Drift:

Less than 5% per year.

Typical Life:

3 years in normal service.

Warranty:

1 year.

Hydrogen Sulfide (5100-05)

Range:

0 - 100 PPM

Operating Temperature -40

o

F to 122

o

F (-40

o

C to +50

o

C)

Relative Humidity

10 - 99% RH

Accuracy:

+/- 2 PPM

Response:

<30 seconds to 50% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 1% per month

Typical Life:

3 years in normal service

Warranty:

1 year

Note:

Only Combustible Gas (5100-02) and Electrochemical
sensor Hydrogen Sulfide (5100-05) are FMRC Approved

Hydrogen Sulfide (5100-01)

Range:

Factory 100 PPM, Max. 100 PPM

Operating Temperature -40

o

F to 158

o

F (-40

o

C to 70

o

C)

Relative Humidity

5 - 99% RH

Response:

<60 seconds to 90% indication

Calibration Frequency

Monthly, Recommended

Zero Drift:

Less than 5% per year.

Typical Life:

3 years in normal service.

Warranty:

1 year.

Oxygen (5100-03)

Range:

Factory 25% O

2

, Max. 25% O

2

Operating Temperature -19

o

F to 122

o

F (-7

o

C to 50

o

C)

Relative Humidity

5 - 99% RH

Response:

10 seconds to 90% indication.

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 5% per year.

Typical Life:

1 year in normal service.

Warranty:

1 year

Carbon Monoxide (5100-04)

Range:

Factory 500 PPM, Max. 2,000 PPM

Operating Temperature 4

o

F to 122

o

F (-20

o

C to 50

o

C)

Relative Humidity

15 - 99% RH

Response:

<25 seconds to 90% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 1% per month

Typical Life:

2 years in normal service

Warranty:

1 year

Chlorine (5100-06)

Range:

Factory 10 PPM, Max. 100 PPM

Operating Temperature 4

o

F to 122

o

F (-20

o

C to 50

o

C)

Relative Humidity

15 - 99% RH

Response:

<60 seconds to 90% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 1% per month

Typical Life:

2 years in normal service

Warranty:

1 year

Hydrogen (5100-07)

Range:

Factory 1,000 PPM, Max 2,000 PPM

Operating Temperature 4

o

F to 122

o

F (-20

o

C to 50

o

C)

Relative Humidity

15 - 99% RH

Response:

<30 seconds to 90% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 1% per month

Typical Life:

2 years in normal service

Warranty:

1 year

Sulfur Dioxide (5100-10)

Range:

Factory 100 PPM, Max 100 PPM

Operating Temperature 4

o

F to 122

o

F (-20

o

C to 50

o

C)

Relative Humidity

15 - 99% RH

Response:

<20 seconds to 90% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 1% per month

Typical Life:

2 years in normal service

Warranty:

1 year

Nitrogen Dioxide (5100-12)

Range:

Factory 20 PPM, Max 100 PPM

Operating Temperature 4

o

F to 122

o

F (-20

o

C to 50

o

C)

Relative Humidity

15 - 99% RH

Response:

<35 seconds to 90% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 1% per month

Typical Life:

2 years in normal service

Warranty:

1 year

Carbon Monoxide (5100-13)

Range:

Factory 1,000 PPM, Max 2,000 PPM

Operating Temperature 4

o

F to 122

o

F (-20

o

C to 50

o

C)

Relative Humidity

15 - 99% RH

Response:

<25 seconds to 90% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 2% per month

Typical Life:

3 years in normal service

Warranty:

1 year

Carbon Monoxide (5100-16)

Range:

Factory 2,00 PPM, Max 4,000 PPM
Tolerates Hydrogen to 2,000 PPM

Operating Temperature 4

o

F to 122

o

F (-20

o

C to 50

o

C)

Relative Humidity

15 - 99% RH

Response:

<35 seconds to 90% indication

Calibration Frequency

90 Days, Recommended

Zero Drift:

Less than 1% per month

Typical Life:

2 years in normal service

Warranty:

1 year