D-a90(v)/d-a93(v)/d-a96(v) direct mounting style, Reed switch direct mounting style, Caution – SMC Networks Reed Switch Solid State Switches User Manual

Page 10: Auto switch specifications, Weight, Dimensions, Grommet electrical entry: in-line, Precautions, D-a90, d-a90v (without indicator light)

background image

( ): dimensions for D-A93.

D-A90V, D-A93V, D-A96V

Auto Switch Specifications

Grommet

Electrical entry: In-line

PLC: Abbreviation of Programmable Logic Controller

D-A90, D-A90V (Without indicator light)

Auto switch model

Applicable load

Load voltage

Maximum load current

Contact protection circuit

Internal resistance

D-A93, D-A93V, D-A96, D-A96V (With indicator light)

Auto switch model

Applicable load

Load voltage

Load current range and
Maximum load current

Contact protection circuit

Internal voltage drop

Indicator light

D-A90, D-A90V

IC circuit, Relay, PLC

24 V or less

50 mA

None

1 Ω or less (Including lead wire length of 3 m)

48 V or less

40 mA

100 V or less

20 mA

D-A93, D-A93V

Relay, PLC

24 VDC

5 to 40 mA

None

D-A93 —— 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA)

D-A93V —— 2.7 V or less

Red LED lights when ON.

100 VAC

5 to 20 mA

D-A96, D-A96V

IC circuit

4 to 8 VDC

20 mA

0.8 V or less

AC
DC

AC
DC

AC
DC

Note 1) Operating load is an induction load.
Note 2) Wiring to the load is 5 m or longer.
Note 3) Load voltage is 100 VAC.
Use the contact protection box in any of the
above listed situations. The contact point life may
decrease. (Refer to page 12-13-5 for contact
protection box.)

1. Fix the switch with appropriate screw

installed on the switch body. If using other
screws, switch may be damaged.

Model

Lead wire length: 0.5 m

Lead wire length: 3 m

D-A90

6

30

D-A90V

6

30

D-A93

6

30

D-A93V

6

30

D-A96

8

41

D-A96V

8

41

(g)

Weight

Auto Switch Internal Circuit
Colors of lead wire inside ( ) are the
ones before conformed to IEC standard.

D-A90V

D-A93V

D-A96V

Reed switch

OUT(±)
Brown

ȁ

OUT (±)
Blue

Blue (Black)

LED

Reed switch

Resistor

Zener diode

Brown (Red)

OUT (

+

)

Brown

ȁ

OUT (

)

Blue

LED

Reed switch

Resistor

Reverse
current
prevention
diode

OUT
Black

DC (

+

)

Brown

DC (

)

Blue

Load

(

+

)

(

)

DC
power supply

Dimensions

D-A90, D-A93, D-A96

(3)

• Lead wire

D-A90(V)/D-A93(V)—Oil resistant vinyl heavy-duty cord, ø2.7, 0.18 mm

2

x 2 cores (Brown, Blue), 0.5 m

D-A96(V)—Oil resistant vinyl heavy-duty cord, ø2.7, 0.15 mm

2

x 3 cores (Brown, Black, Blue), 0.5 m

Note 1) Regarding the common specifications of the reed switches, refer to page 12-13-5.
Note 2) Regarding the lead wire length, refer to page 12-13-5.
Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator

light will not be possible where the output signal is less than 2.5 mA. However, there is no
problem in terms of contact output, when an output signal exceeds 1 mA or more.

M2.5 x 4

l

Slotted set screw

Indicator light

D-A90 without indicator light

Indicator light

D-A90V without indicator light

M2.5 x 4

l

Slotted set screw

Most sensitive position

Reed Switch
Direct Mounting Style

D-A90(V)/D-A93(V)/D-A96(V)

Contact
protection
box
CD-P11
CD-P12

Contact
protection
box
CD-P11
CD-P12

Most sensitive

position

Precautions

Caution

For details about certified products
conforming to international standards,
visit us at www.smcworld.com.

12-13-10

1st

12_13_D-.qxd 04.7.6 18:02 Page 13-10