Note:

• Normally, the filter cleaning unit automatically starts cleaning

the mesh filter either while cooling down the projector after
the power was turned off or after restarting the projector.

• When the icon as shown in Fig.3 appeared for the first time,

replace the filters as soon as possible. If you turn off the
projector before you replace the filters, the projector will turn
off 3 minutes after the power is turned on next time.

This icon is warning you that the

remaining time has reached 0% and

the filters need to be replaced as soon

as possible.

Fig.3

Note:

Fig.1, Fig. 2, and Fig. 3 appear at turning on and selecting input

source.

• Fig.1, Fig. 2, and Fig. 3 will not appear when the Display

function is set to Off (p.54) or during “Freeze” (p.31).

This icon is warning you that the

remaining time has reached 10%.

Fig.2

This function is used to set a frequency for the filter

replacement.

Use the Point ed buttons to select Filter counter and

then press the Point 8

or the SELECT button to access the

submenu items.

Filter counter . . . . . . . . . Shows the total used filter time.

The filter counter is displayed in

red when filter counter exceeded

the time specified for Filter counter

timer, or filter clogging was

detected.

Filter counter remaining ... Shows the remaining time every

10% until the specified time

comes. (p.74). When the remaining

time reached 10%, it is displayed in

red.

Filter counter timer. . . . . To set the timing of replacing with

a new filter. The filter replacement

icon appears when filter counter

exceeded the specified time or

filter clogging was detected.

(Options available for the mesh

filter:

Off/4000H/8000H/12000H/16000H,

Options available for an optional

smoke resistant filter:

Off/10H/15H/

20H)

Filter counter reset . . . . . To reset the filter counter. Select

Reset, press the SELECT button,

and select Yes in the confirmation

box (p.74).

Auto cleaning timer . . . . To schedule a filter cleaning task

when the length of time you used

the filter reached the specified

time. (Options: 50H, 100H(default),

150H).

Fig.1

Press the SELECT button to select Filter counter

timer and use the Point ed buttons to set

the timer. Select from (Off/ 4000H/ 8000H/

12000H/16000H) depending on the use

environment.

Settings

Filter counter

This icon is warning you that the

remaining time has exceeded the

specified time.