2-31

Programming

Terminal Specific RS-232C

Three RS-232C hosts are set up with their own fixed format options. Selecting
the ICL, Fujitsu or Nixdorf RS-232C terminal will set the defaults listed below.

Table 2-5. Terminal Specific Defaults

Parameter

Standard

ICL

FUJITSU

NIXDORF

Transmit Code ID

No

Yes

Yes

Yes

Data Transmission Format

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Suffix

CR/LF (7013)

CR (1013)

CR (1013)

CR (1013)

Baud Rate

9600

9600

9600

9600

Parity

Even

Even

None

Odd

Hardware Handshaking

None

None

None

None

Software Handshaking

None

None

None

None

Stop Bit Select

Two

One

One

One

ASCII Format

7-Bit

8-Bit

8-Bit

8-Bit

Beep On

Disabled

Disabled

Disabled

Disabled

RTS Line State

Low

High

Low

Low

RS-232C UPC-A Code ID

“A”

“A”

“A”

“A”

RS-232C UPC-E Code ID

“A”

“E”

“E”

“C0”

RS-232C EAN-8 Code ID

“A”

“FF”

“FF”

“B”

RS-232C EAN-13 Code ID

“A”

“F”

“F”

“A”

RS-232C Code 39 Code ID

“B”

“C”

None

“M”

RS-232C Codabar Code ID

“C”

“N”

None

“N”

RS-232C Code 128 Code ID

“D”

None

None

“K”

RS-232C I 2 of 5 Code ID

“F”

“I”

None

“I”

RS-232C MSI/Plessey Code ID

“J”

None

None

“O”