Programming

• Decode Options (Continued)

Code 39 Buffering (Scan & Store)

When you select the scan and store option, all Code 39 symbols having a
leading space as a first character are temporarily buffered in the unit to be
transmitted later. The leading space is not buffered.

Decode of a valid Code 39 symbol with no leading space causes transmission
in sequence of all buffered data in a first-in first-out format, plus transmission
of the “triggering” symbol. See

page 2-21

for further details.

When the scan and transmit option is selected, decoded Code 39 symbols
without leading spaces are transmitted without being stored in the buffer.

Scan and Store affects Code 39 decodes only. If you select scan and store, it is
recommended that you configure the scanner to decode Code 39 symbology
only.

Beep After Good Decode

Determine if the unit beeper will sound during normal scanning. Usually it is

desirable to operate the unit with the beeper enabled. In all cases, the beeper
operates during parameter menu scanning and indicates error conditions.

Beeper indications begin on

page 2-19

.

CLSI Editing

This parameter strips the start and stop characters, then inserts a space after the
1st, 5th, and 10th characters of a 14-character Codabar symbol. Symbol length
does not include start and stop characters.

NOTIS Editing

This option strips the start and stop characters from decoded Codabar