beautypg.com

Parameter descriptions, Set parameter defaults, Host interface code – Symbol Technologies LS 3603 User Manual

Page 32: Code types, Code lengths, Parameter descriptions -4

background image

2-4

LS 3603 Product Reference Guide

Parameter Descriptions

• Set Parameter Defaults

Scanning the SET ALL DEFAULTS bar code on

page 3-3

returns all parameters

to the values listed in the Default Table. (See

page 2-29

.)

• Host Interface Code

Scan the bar code corresponding to your host type. You must select a host type
when you first set up the scanner and whenever you change host types.

• Code Types

The bar code menu selections enable the scanner to decode any or all of the

following symbologies.

UPC Versions A and E (EAN 8 and 13)

Codabar

Code 39

Code 39 Full ASCII

Discrete 2 of 5

Interleaved 2 of 5

Code 128

MSI Plessey

EAN 128

Code 93

The scanner will autodiscriminate between all of the above symbologies,
except for Code 39 and Code 39 Full ASCII.

• Code Lengths

Select one or two lengths for the Interleaved or Discrete 2 of 5 codes. Determine
the number of characters represented in the Discrete 2 of 5 or Interleaved 2 of
5 bar codes by counting the number of printed (i.e., human readable) digits
beneath the bar code. Set one or both lengths, one per scanning sequence. For
D 2 of 5, LENGTH 1 may range from 02-55 and LENGTH 2 from 00-55. For
I 2 of 5, LENGTH 1 may range from 02-54 and LENGTH 2 from 00-54.