Rem - go to remote, Run - start running, Stp - stop running – SIGMA LBA-708 User Manual

Page 261: Stt - start/stop toggle, Syc - synchronize with remote

background image

Operator’s Manual

LBA-PC

Doc. No. 10654-001, Rev 4.10

261

A.5.4.18 REM - go to remote

When the REM message is sent or when the LBA-PC goes from local to remote via the REN line

then local control is automatically locked out (equivalent to password lockout).
Note that remote logging (:LOG) or synchronization (:SYC) are allowed only when remote is

enabled. If remote logging was enabled in the configuration (i.e. file name was FRM, RDD, or

RDR) and you set the LBA-PC to remote, then remote logging will be re-enabled. The

synchronization state is not kept in the configuration so you must send a new SYC command

after the LBA-PC is in remote.

:REM

Returns:

REM

A.5.4.19 RUN - start running

This command has no effect if the LBA-PC is already running.

:RUN

A.5.4.20 STP - stop running

This command has no effect if the LBA-PC is already stopped.

:STP

A.5.4.21 STT - start/stop toggle

Toggle start/stop equivalent to Start/Stop on main LBA-PC menu.

:STT

A.5.4.22 SYC - synchronize with remote

SYC forces the LBA-PC to wait until data, results, or both have been queried and sent before

capturing another frame. This command is similar to :LOG with the file name set to FRM, RDD,

or RDR, except the LBA-PC does not automatically send the response data.

:SYC

3

Key Type Value

Description

Data

B

true = synchronize remote data download
Do not capture another frame until the

controller sends a :FRM? or :RDD?

Command and reads the response data.
false = normal operation