Frm - upload/download a data frame – SIGMA LBA-708 User Manual
Page 250
Message Generated
By
%s detected but cannot be initialized. LBA-PC set
to Off-Line mode.
device driver
Unable to load LCA program file (%s).
device driver
Press OK to stop Auto Calibration.
ultracal
A.5.4.6 FRM - upload/download a data frame
Only one frame at a time can be uploaded or downloaded. :FRM will upload a frame of data
from the controller to the LBA-PC, while :FRM? will download a frame of data from the LBA-PC to
the controller. Data is uploaded to or downloaded from the LBA-PC’s frame buffer.
:FRM?
→ CONTROLLER)
Key Type Value
Description
FrameNumber I frame
number
-1 = gain frame
0 = reference frame
1 to n. ‘n’ is the size of the frame buffer.
default = current frame
Returns:
FRM FrameNumber=f;#dn..n(DAB)(DAB)…(DAB)(DAB)
Where:
f = frame
number
# = pound
symbol
d
=
number of digits to follow in n..n
n..n
=
number of data bytes
(DAB) =
data byte - 8-bit data byte
:FRM [FrameNumber=f;][Replace=B;]#dn..n(DAB)(DAB)…(DAB)(DAB)
:FRM
→ LBA300PC)
(DAB)(DAB)…(DAB)(DAB) must be exactly what was returned by a previous :FRM? command.
Where:
f = frame
number
# = pound
symbol
Operator’s Manual
LBA-PC
250
d
=
number of digits to follow in n..n