beautypg.com

1 panel pc 670 – Siemens PC 870 User Manual

Page 34

background image

Maintenance

4-2

SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual

Edition 07/01

4.2

Detaching the operating unit from the computing unit

It may at some stage become necessary to separate the operating unit
from the computing unit, e.g. to replace the operating unit.

4.2.1

Panel PC 670

To swing the computing unit away from the operating unit, proceed as
follows:

1.

Undo the knurled screws which secure the computing unit to the
rear side of the operating unit.

2.

Swing the computing unit away to the left, whereby the two left clips
act as hinges and thus prevent an unintentional releasing of the
computing unit:

Mounting rail

Computing

unit swung away by 90

°

Computing unit

Clips

Mounting rail

Compu-
ting unit

Opera-
ting unit

Fig. 4-1

Swinging the computing unit away from the operating unit (viewed from above)

You can now access the connections on the rear panel of the operating
unit.

Swinging open the
computing unit