Video loss detection – Speco Technologies DVR-PC8 Series User Manual
Page 49

49
 
 
6.3.9. Video loss Detection
 
Video loss Detection 
Select this category and the screen title will appear as “Video loss” when the 
camera cable is disconnected or cut. The alarm time will follow Sensor 
Recording Time. 
 
Recording Failure Alarm 
Turn on sensor output Number 7 (located second to the end) from internal 
system while the recording activity is normal at the system. This function turns 
off the Relay when a problem occurs or the recording stops. 
 
Use the External Output No.2 
Configure this function when there is Video loss. 
 
Recording Failure Alarm 
Reboots the system after warning alarm if the DVR fails to record. 
 
Use the External output No.1 
When System is recording it turns on Relay No.15. This function turns off the 
relay if there is any problem with record. 
When user manually stops the recording, the alarm doesn’t activate. 
No.15 Relay can’t be used with other functions while using it as an External 
output.
Note
Numbers can be changed by the number of camera channels.
 
 