Select sensor, Sensor type, Sensor recording time – Speco Technologies DVR-PC8 Series User Manual
Page 47: Use no.4 sensor for auto shutdown
47
6.3.3. Select Sensor
Select sensor for setting.
Cameras Associated with Selected Sensor
Select the camera to be associated to the installed sensor. Multiple cameras
can be connected to a single sensor. Activate sensor by clicking the desired
sensor with the mouse. Then, select the camera number for the connecting
sensor.
PTZ Preset
To set the Preset location of the camera, assign the number at the bottom of
the camera.
External Output connected to each Sensor
When sensors detect any motion and are connected to a pre-selected alarm,
the alarm can be automatically triggered. When there is intrusion, the sensor
will be detected and the alarm output port will automatically halt. Select sensor
and camera. Then, select the alarm output port to use. The connected alarm
output port in the P series will be shown as activating and the chosen alarm
output port will change to red color.
.
6.3.4. Sensor Type
Select the type of sensors to be preset on alarm from the N/C (Normal Close)
or N/O (Normal Open). Only one type can be selected.
6.3.5. Sensor Recording Time
Sets the preset duration for recording time when a sensor is triggered.
Maximum recording time is 5 minutes. When the preset recording time is up,
the recording of images detected by sensors halt and the system returns to
the previous recording mode until the sensor is triggered.
6.3.6. Use No.4 sensor for Auto Shutdown
In case the power supply fails, the Auto-Shutdown functions and the system
shut down safely. The user can set up when the use the Auto-Shutdown (UPS
battery backup time) during the discontinuous of power supply. Inquire from
the place of purchase for the UPS used.
For example, when the UPS battery is set for 1 minute, the system shut down
safely after power supply excess 1 minute.