7 no connection via com1/tty possible – Siemens C79000 Z7076 C638 04 User Manual

Page 56

background image

Error Diagnosis and Reinstallation

6-6

SIMATIC Box PC 620 Operating Manual

C79000-Z7076-C638-04

Error Message on the Screen

Meaning/Suggestion

Incorrect Drive B type
Run SETUP

Check the SETUP entries for drive B.

Diskette drive A error

Error accessing drive A.
Contact your technical support team.

Diskette drive B error

Error accessing drive B.
Contact your technical support team.

Failure Fixed Disk

Error accessing the hard drive.
Check the SETUP settings
Contact your technical support team.

Keyboard error

Check whether the keyboard is connected correctly.

Stuck Key

Check whether a key on the keyboard is stuck.

System RAM Failed at offset:

Memory error
Contact your technical support team.

Shadow RAM Failed at offset:

Memory error
Contact your technical support team

Extended RAM Failed at offset:

Memory error
Contact your technical support team

Failing Bits:

Memory error
Contact your technical support team

Operating system not found

Possible causes:
No operating system present
Incorrect drive addressed (diskette in drive A/B)
Incorrect active boot partition
Incorrect entries in SETUP for the BOOT drive

Previous boot incomplete
Default configuration used

Abort of the previous BOOT procedure, for example, due to a power
failure. Check the hardware settings and the SETUP.

System cache error
Cache disabled

Error in the CPU’s cache module.
Contact your technical support team.

Monitor type does not match
CMOS
Run SETUP

The monitor does not match the SETUP entries.
Adapt the SETUP entries to the monitor.

System timer error

Hardware error
Contact your technical support team.

Real time clock error

Clock chip error
Contact your technical support team.

Keyboard controller error

Keyboard error
Contact your technical support team.

6.7

No Connection via COM1/TTY Possible

Cause and Remedy

The COM1 interface is set to the V24 mode. In the Setup menu Advanced >
COM/LPT Configuration
set the parameter COM1 TTY to enabled.