2 export 50 hz power options, Export 50 hz power options – Sundance Spas 680 User Manual
Page 18

Page 12
680 SERIES
Export Burlington, Denali and Tacoma 1-Pump Models (50 Hz)
230V/20A*
230V/30A**
Voltage:
230 VAC
230 VAC
# of Wires:
3
3
Frequency:
50 Hz
50 Hz
Current Draw:
15A
21A
Circuit Breaker:
20A
30A
* In the 20A configuration, the heater will not operate while the jets pump
is running in high speed. This is the factory setting.
** In the 30A configuration, the heater will operate while the jets pump is
running in high speed.
Export Hartford and Hawthorne 2-Pump Models (50 Hz)
230V/20A*
230V/30A**
230V/40A***
Voltage:
230 VAC
230 VAC
230 VAC
# of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
Circuit Breaker:
20A
30A
40A
* In the 20A configuration, the heater will not operate while either jets pump
is running in high speed. This is the factory setting.
** In the 30A configuration, the heater will not operate while both jets pumps
are running in high speed.
*** In the 40A configuration, the heater will operate while both jets pumps are
running in high speed.
5.2 Export 50 Hz Power Options