beautypg.com

2 export 50 hz power options, Export 50 hz power options – Sundance Spas 680 User Manual

Page 18

background image

Page 12

680 SERIES

Export Burlington, Denali and Tacoma 1-Pump Models (50 Hz)

230V/20A*

230V/30A**

Voltage:

230 VAC

230 VAC

# of Wires:

3

3

Frequency:

50 Hz

50 Hz

Current Draw:

15A

21A

Circuit Breaker:

20A

30A

* In the 20A configuration, the heater will not operate while the jets pump

is running in high speed. This is the factory setting.

** In the 30A configuration, the heater will operate while the jets pump is

running in high speed.

Export Hartford and Hawthorne 2-Pump Models (50 Hz)

230V/20A*

230V/30A**

230V/40A***

Voltage:

230 VAC

230 VAC

230 VAC

# of Wires:

3

3

3

Frequency:

50 Hz

50 Hz

50 Hz

Current Draw:

15A

23A

29A

Circuit Breaker:

20A

30A

40A

* In the 20A configuration, the heater will not operate while either jets pump

is running in high speed. This is the factory setting.

** In the 30A configuration, the heater will not operate while both jets pumps

are running in high speed.

*** In the 40A configuration, the heater will operate while both jets pumps are

running in high speed.

5.2 Export 50 Hz Power Options