Sundance Spas 680 User Manual
Page 17

Page 11
680 SERIES
North American Burlington 1-Pump Models (60 Hz)
240V/40A*
240V/50A**
Voltage:
240 VAC
240 VAC
# of Wires:
3
3
Frequency:
60 Hz
60 Hz
Current Draw:
26A
36A
Circuit Breaker:
40A, 2-Pole
50A, 2-Pole
* In the 40A configuration, the heater will not operate while the jets pump is
running in high speed.
** In the 50A configuration, the heater will operate while the jets pump is
running in high speed. This is the factory setting.
North American Hartford and Hawthorne 2-Pump Models (60 Hz)
240V/40A*
240V/50A**
240V/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
Circuit Breaker:
40A, 2-Pole
50A, 2-Pole
60A, 2-Pole
* In 40A configuration, the heater will not operate while either jets pump is
running in high speed. Note: pump 2 runs only in high speed.
** In 50A configuration, the heater will not operate while both jets pumps are
running in high speed. Note: pump 2 runs only in high speed. This is
the factory setting.
*** In 60A configuration, the heater will operate while both jets pumps are
running in high speed. Note: pump 2 runs only in high speed.