beautypg.com

Sundance Spas 680 User Manual

Page 17

background image

Page 11

680 SERIES

North American Burlington 1-Pump Models (60 Hz)

240V/40A*

240V/50A**

Voltage:

240 VAC

240 VAC

# of Wires:

3

3

Frequency:

60 Hz

60 Hz

Current Draw:

26A

36A

Circuit Breaker:

40A, 2-Pole

50A, 2-Pole

* In the 40A configuration, the heater will not operate while the jets pump is

running in high speed.

** In the 50A configuration, the heater will operate while the jets pump is

running in high speed. This is the factory setting.

North American Hartford and Hawthorne 2-Pump Models (60 Hz)

240V/40A*

240V/50A**

240V/60A***

Voltage:

240 VAC

240 VAC

240 VAC

# of Wires:

3

3

3

Frequency:

60 Hz

60 Hz

60 Hz

Current Draw:

26A

36A

45A

Circuit Breaker:

40A, 2-Pole

50A, 2-Pole

60A, 2-Pole

* In 40A configuration, the heater will not operate while either jets pump is

running in high speed. Note: pump 2 runs only in high speed.

** In 50A configuration, the heater will not operate while both jets pumps are

running in high speed. Note: pump 2 runs only in high speed. This is
the factory setting.

*** In 60A configuration, the heater will operate while both jets pumps are

running in high speed. Note: pump 2 runs only in high speed.