Specifications, 2) major component specifications (a) indoor unit – Sanyo CL2462R User Manual
Page 7
– 7 –
SM830092
2. SPECIFICATIONS
(2)
Major Component Specifications
(A)
Indoor Unit
MODEL No.
KS2462R
Source
230 - 208 V / 1 phase / 60 Hz
Remote controller (Accessory)
RCS - 1PS4U - G
Controller P. C. B Ass'y
CR - KS2462R
Control circuit fuse
250 V, 3 A
Fan
Type
Cross-flow
Number ... Dia. and length
in.
(mm)
1 ... O.D. 4 (100), L33-3/8 (847)
Fan motor
Model
KFG4X - 31B6P-S
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High)
rpm
4 … 1,365
Nominal output
W
30
Coil resistance
Ω
BRW - WHT
: 161.2
,
ORG - YEL
:
26.9
(Ambient temperature 68
°
F)
WHT - VLT
:
11.6
,
YEL
- BLK
:
22.8
VLT
- ORG
:
68.7
,
BLK
- PNK
: 115.2
Safety device
Internal
Operating temperature
Open
°
F
266
±
9
Close
°
F
181
±
27
Run capacitor
VAC,
µ
F
440 V , 1.5
µ
F
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows … Fins per inch
2 … 19.5
Face area
ft.
2
(m
2
)
2.30 (0.214)
Flap Motor
Type
Stepping motor
Model ... Q’ty
MP24GA2 ... 2
Step angle
5.625 deg / step
Rating
V
DC 12 V
Coil resistance (Ambient temperature 77
°
F)
Ω
400
±
7 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE