Ultra Fast USB 2.0 Multi-Format Flash Media Controller/USB Hub Combo

SMSC USB2640/USB2641

31

Revision 2.0 (10-03-08)

DATASHEET

7.3.2.5

22h-5Dh: USB Manufacturer String Length

7.3.2.6

5Eh-99h: USB Product String Length

Note 7.2

While the full strings are reported during USB enumeration, Windows XP/Vista reads
concatenated version of the strings from the standard SCSI inquiry response when storing
the values for display in the Windows registry and device manager.

7.3.2.7

9Ah: USB BmAttribute (1 byte)

BYTE

NUMBER

BYTE NAME

DESCRIPTION

59:0

USB_MFR_STR

Manufacturer String Length

Maximum string length is 28 characters.

(See

Note 7.2

below)

BYTE

NUMBER

BYTE NAME

DESCRIPTION

59:0

USB_PRD_STR

Product String Length

This string will be used during the USB enumeration process in Windows.

Maximum string length is 28 characters.

(See

Note 7.2

below)

BYTE

NUMBER

BYTE NAME

DESCRIPTION

7:0

USB_BM_ATT

Self- or Bus-Power: Selects between Self- and Bus-Powered operation.

The hub is either Self-Powered (draws less than 2 mA of upstream bus

power) or Bus-Powered (limited to a 100 mA maximum of upstream power

prior to being configured by the host controller).

When configured as a Bus-Powered device, the SMSC hub consumes less

than 100 mA of current prior to being configured. After configuration, the

Bus-Powered SMSC hub (along with all associated hub circuitry, any

embedded devices if part of a compound device, and 100 mA per externally

available downstream port) must consume no more than 500 mA of

upstream VBUS current. The current consumption is system dependent, and

the OEM must ensure that the USB 2.0 specifications are not violated.

When configured as a Self-Powered device, <1 mA of upstream VBUS

current is consumed and all ports are available, with each port being capable

of sourcing 500 mA of current.

80 = Bus-Powered operation

c0 = Self-Powered operation

A0 = Bus-Powered operation with remote wake-up

E0 = Self-Powered operation with remote wake-up