Configuration

51

Siemens Building Technologies

Fire Safety & Security Products

01.2009


7.9.3

Forbidden Protocol

ICMP or UDP protocol can be rejected by firewall if assigned.

7.10 System

7.10.1 Setting

CGI-Lock is a system security setting. It means you can activate or deactivate the
login data for the CGI-commands. If you set ON, you always have to enter an ID
and password for the web-page, but besides you can change everything using the
cgi-commands. Otherwise, it’s not necessary for the login data if you choose OFF.

7.10.2 Update

You can update system firmware once the update file is available. It is the
customer's responsibility to update firmware. All camera motions will shut down
during firmware update. Close any other screens before starting a firmware update.
Never disconnect power and LAN cable during the firmware update process.
Rebooting the camera after firmware update may take approx. 15 minutes.

SIGNALWORT

The power supply to the camera must not be interrupted during the SW update.
Otherwise the camera will be damaged and have to be returned to the workshop
for repair.

.