beautypg.com

1 external digital input 1, 2 external digital input 2 – Siemens CCMX1315-LP User Manual

Page 34

background image

Configuration

34

Siemens Building Technologies

Fire Safety & Security Products

01.2009


7.4.1

External digital input 1

z

Set an "Alarm Input"
ON: Detects an external alarm.
OFF: Does not perform alarm detection.

Î

The following functions will be enabled if “ Alarm Input” is set to “ON”

z

Set "Input type" for alarms
Normally Open (NO): A dry-contact detecting way, opened if nothing occurs but
closed in case of an alarm.
Normally Closed (NC): A dry-contact detecting way, closed if nothing occurs but
open in case of an alarm.

z

Set "TEXT Enable" for alarms
A noticeable message of alarm can be displayed on screen if this item is set to
“ON”.

z

Enter "Text" for alarm message
Max 24 characters can be entered.

z

Set "Audio out" for alarm message
An audio alarm message can be sent to an external speaker if this item set to
“ON”.

NOTE
A speaker with integrated amplifier can be connected to the AUDIO out jack on the rear panel.

z

Select "EVENT”
Pre-recorded voice files with extension .wav that have been uploaded to SD
memory card in advance can be selected as voice alarm message. Up to 4 kinds
of audio source can be selected.

7.4.2

External digital input 2

All configurations are the same as for Alarm digital 1, except that an additional
input mode – enforced BW – is added, which will switch the camera to
monochrome mode if a trigger signal is received.