Configuration
23
Siemens Building Technologies
Fire Safety & Security Products
01.2009
MPEG4
The following settings are enabled when "Compression Mode " is set to "MPEG4".
z
Resolution: 640 x480 and 320 x240 available.
z
Bit Rate: 6 modes including 256, 512, 1024, 2048, 3072 and 4096 kb/s.
z
GOP: default is 29. It means 1 I frame plus 28 P frame. End user can adjust
1~64 level.
Unicast Streaming
Ready for MPEG4 and JPEG streaming
z
RTSP Port Number – specify the port number you would like to use for RTSP
protocol, default is 554
z
VIDEO Port Number - specify the port number you would like to use for video
streaming, default is 5000
Multicast Streaming
Ready for MPEG4 and JPEG streaming
z
Multicast Address: specify the multicast address
z
RTSP Port Number – specify the port number you would like to use for RTSP
protocol, default is 554
z
VIDEO Port Number - specify the port number you would like to use for video
streaming, default is 5000