Page 33
Configuration
33
Siemens Building Technologies
Fire Safety & Security Products
01.2009
7.3.4
Camera OSD settings
This function sets up the text position and colour of the camera name, alarm text or
DATE/TIME on the screen. Of course, the corresponding ENABLE flag for each
item shall be ”ON” to activate this function, such as camera name Enable in
Network setup, Text enable in Alarm setting and Display in DATE/TIME setting.
When the OSD is off, the message "OSD" will be overlaid in red. Masking is only
possible when the OSD is off. Make sure not to select the same position for alarm
text and date/time display.
7.4
Alarm
External alarms and motion sensors can be set. Connecting a sensor or other
device to the alarm input terminal signals an alarm when the sensor detects
trouble. For example, mounting a sensor on a door notifies an alarm each time the
door is opened. By setting the motion sensor to activate, an alarm is notified by
detecting a change in a screen.
Two alarm digital input terminals AL1, AL2 are located on the rear panel. Before
using the alarm function certain parameters need to be defined.