2 troubles not to be warned by indicators – JVC BR-D95U User Manual
Page 74

146
14 TROUBLESHOOTING
14-1 WARNINGS WITH INDICATORS
Warning
On-screen display
Warningcode information
Behavior and actions to be taken
code
41 1
CASSETTE EJECT
Cassette does not come
(AUTO OFF)
FAILURE
out in Eject.
56 1~
TAPE DEFECTIVE
Tape defect.
56 9
Tape loose
57 1~
END LEADER
Tape end sensor abnormal.
57 2
DETECTION
58 1~
BEGIN LEADER
Tape beginning sensor
58 2
DETECTION
abnormal.
70 1
DRUM MOTOR
Drum stops motion.
(AUTO OFF)
FAILURE
71 1
CAPSTAN MOTOR
Capstan stops its motion.
(AUTO OFF)
FAILURE
72 1~
SUP REEL MOTOR
Supply reel motor motion
72 8
FAILURE
abnormal.
(AUTO OFF)
73 1~
TU REEL MOTOR
Takeup reel motor motion
73 8
FAILURE
abnormal.
(AUTO OFF)
Behavior: Only warning indicator is active.
Action:
Consult your local JVC dealer.
When the MENU button is pressed, the
indication goes out.
Behavior: Stops, with no operation possible.
Action:
Turn the power off and then on.
Behavior: Cassette ejected.
Action:
If no abnormality is found in tape,
reload the cassette.
If there are any abnormalities when the self-diagnostics run after the power is turned on, the following warning indications are
shown. Self-diagnostics are executed when menu switch No. 357
shown in 6 digits. “ x ” mark shows unspecified.
Behavior: Stops, with no operation possible.
Action:
Turn the power off and then on.
Behavior: Stops, with no operation possible.
Action:
Turn the power off and then on.
Behavior: Stops, with no operation possible.
Action:
Turn the power off and then on.
Behavior: Stops, with no operation possible.
Action:
Turn the power off and then on.
Behavior: Tape is fast-forwarded. If tape
begin is still detected 3 seconds
later, cassette is ejected.
Action:
Reload the cassette.
Behavior: Tape is rewound. If tape end is still
detected 3 seconds later, cassette
is ejected.
Action:
Reload the cassette.
80xxxx
CPU BUS FAILURE
Signal communication
between VCR’s micro-
processors abnormal.
820100
EEPROM FAILURE
EEPROM signal
820300
communication in VCR
abnormal.
840100
SYSCON REF FAILURE
System controller reference
signal failure.
850100
M/S REF
Mechanical controller
FAILURE
reference signal failure.
860100
TC REF FAILURE
Time code reference failure.
C0xxxx
MECHA(NO TAPE)
*1 Abnormal mechanical
FAILURE
operation.
On-screen display
DIAG WARNING 800400
CPU BUS FAILURE
(PUSH MENU KEY)
* Serial digital signals are used in conformity
with SMPTE259M for video and with AES/
EBU for audio.
*1 If the C02XXX indicator appears when the
power is turned ON it means that
condensation has occurred. Press the
[MENU] button until the indicator goes out.
Once the indicator has gone out, you can
operate the unit as usual.
147
14 TROUBLESHOOTING
14-2 TROUBLES NOT TO BE WARNED BY INDICATORS
Symptoms
Cause
Action
Not operable
Not recordable
Playback impossible
On-screen display does
not come up
Noise appears on part of
the playback picture.
Tape counter does not run.
Menu setting cannot be
changed.
● Set [REMOTE] button to “LOCAL”.
● Set Menu switch No. 002 LOCK> to “OFF”. ● Press [MENU] button to restore normal mode. ● Set cassette’s protective slider to “REC”. ● Set menu switch No. 351 to
“OFF”.
● S-VHS/VHS cassette not acceptable
● Connect monitor to [LINE2-SUPER OUT].
● Set [ON SCREEN] switch to ON.
● Clean the heads as instructed on page 11.
● Set menu switch No. 005 ING> to “ON”. If noise appears when set to “ON”, set to “OFF” and perform manual tracking ● Set menu switch No. 112 “NORMAL”. ● Press [MENU] button and enter Tape Counter mode. ● Set menu switch No. 00D
adjustment.
to “OFF”.
● The [REMOTE] button is set to “Remote”.
● Menu switch No. 002 LOCK > set to“ ON” ● Menu setting mode entered ● Protective slider on the cassette not at “REC” ● Menu switch No. 351 is set
to “VID-ON” or “AUD-ON”.
● S-VHS/VHS cassette in use
● Monitor not connected to [LINE2-SUPER
OUT]
● [ON SCREEN] switch on the sub panel set
to OFF.
● The heads are dirty.
● Menu switch No. 005
set to “OFF”.
● Menu switch No. 112
“NO CONCEAL” or “NO CORRECTION”
● CTL counter does not run on a non-
recorded section of the tape as no CTL
signal is recorded on such a section.
● Counter is in Menu Switch Setting mode.
● Menu switch No. 00D