5 on- screen display – JVC BR-D95U User Manual
Page 12

22
M
H
F
S
CONDITION
CTL
P.READ
AUTO OFF
V.VAR
REMOTE
PB/EE
16:9
TC UB DF SERVO
GEN
CF
AP
525
625
2-4 COUNTER DISPLAY
2 CONTROLS, CONNECTORS AND DISPLAYS
Indicator section
[VCON] button
* During swap editing, player information is shown only by the
indicators in the section when the player is selected. The [AUTO
OFF] indicator always shows recorder information.
Indication
Meaning when lit
CTL
The CTL counter is shown.
TC
The time code is shown.
UB
The user bits are shown.
DF
The CTL counter or time code is in the
drop-frame mode. (525)
SERVO
Servo is stable.
CF
The color frame servo is set. This
indication lights during recording. When
the [CF] switch is ON and a tape with color
frame information is played back, this
indication also lights.
When the PLAYER is selected during
SWAP editing, the [CF] indication does not
light.
GEN
Signals are input to the [REF] connector.
(Blinking) GEN
The input digital audio signals cannot be
recorded correctly because no external
sync signal is input.
16:9
Wide aspect ID signal is being played back.
AP
A non-D-9 tape is played back.
AUTO OFF
A malfunction or abnormality has occurred.
P. READ
The VCR is in the Pre-read mode.
V. VAR
The video parameters can be adjusted.
PB/EE
The PB/EE Auto Switching mode is
selected.
PB
The PB mode is selected.
REMOTE
The VCR is in the Remote mode.
CONDITION
Channel condition is normal.
Minor errors.
Major errors. Normal playback is not
possible.
(Blinking)
Tracking is not correct.
Video signal system
4
525
The NTSC signal system is set.
4
625
The PAL signal system is set.
The video signal system can be set with menu switch No. D95
<525/625> (on the top menu). After selecting the video signal
system, turn this unit OFF then ON again to switch to the
selected video signal system.
The following error messages may be
displayed during swap editing.
Indication
Meaning
Local
The player’s Local/
Remote is set to “Local”.
No Tape
No cassette is loaded in
the VCR.
Bump Error
Bump error occurs.
No Edit Cmd The edit mode is not
selected.
Dur = 0
Duration is set to 0.
Servo Error
Servo error occurs.
Split No A.
The audio insert mode is
not selected.
Rec Inh
Recording is not possible
on this cassette.
IN/OUT Rev
The IN and OUT points
are reversed in terms of
the timeline.
Over 300%
Tape speed is more than
3x.
Over -200%
Reverse tape speed is
more than -2x.
VTR No Play The VCR will not
function.During editing,
the VCR stops.
AuCondition
Editing was interrupted
because of audio
conditions deteriorated.
NO CTL
Stops the operation when
insert editing is executed
in a non-recorded
section.
●
Press the [STOP] button to release
error display indications.
●
“No Tape” indication goes out when a
cassette tape is loaded.
Video/audio control display
* For adjustment of each item, refer to
“Video control adjustment” on page 118.
23
E
Ⅵ Ⅵ Ⅵ Ⅵ F
Remaining time of 15 minutes or more
E
Ⅵ Ⅵ Ⅵ
Remaining time of less than 15 minutes
E
Ⅵ Ⅵ
Remaining time of less than10 minutes
E
Ⅵ
Remaining time of less than 5 minutes
E
Ⅵ
(blinking)
Remaining time of less than 2 minutes
E
(blinking)
Remaining time of less than 1 minutes
No indication
The remaining time is being calculated.
PLAY
R: TCR 00:00:00:01
STOP
TCR 00:00:00:00
SUB TCR 00:00:00:00
2 CONTROLS, CONNECTORS AND DISPLAYS
2-5 ON-SCREEN DISPLAY
1. Tape counter display, etc.
Menu switch No. 504
SUB read-out mode
TC read-out mode
Counter mode
Operation mode
Sub time code
Counter
F
F
F
F
F
On-screen display
On-screen information is available only via the rear
panel [LINE 2 - SUPER OUT] connector.
1. Tape counter display
● Shows data when the [ON SCREEN] switch on
the sub panel is set to ON.
● You can choose what information is shown with
menu switch No. 504
Only time data is displayed when “TIME (0)” is
selected.
Both time data and VCR operation mode are
displayed when “TIME & MODE (1)” is selected.
● The display position can be shifted horizontally
with menu switch No. 501
● Set the [ON SCREEN] switch on the sub panel
to OFF to turn off the on-screen display.
* If menu switch No. 513
is set to “ON”, you cannot turn the on-screen
display off.
● When menu switch No. 504 SELECT> is set to “TIME + SUB TC” or “TIME + 2. Menu switch setting display Press the [MENU] button to call up the menu details, refer to “Menu switch setting” on ● Pressing the [MENU] button restores the normal display. 3. Hour meter data display Hour meter data can be displayed in the Menu 4. Warning code display If a malfunction occurs, the corresponding warning 5. Tape remaining time display When menu switch No. 505 Player/recorder 2. Menu setting display 0002 DH:DRUM HOUR METER 3. Hour meter data display 4. Warning display 5. Tape remaining time display WARNING 02 1 CONDENSATION ON DRUM PLAY CTL 0:00:00:00 E F 008:CAP LOCK(525) SW SEL 002:OPERATION LOCK OFF 003:SYNC SELECT AUTO 005:AUTO TRACKING ON 009:CAP RE-LOCKING DIR. ACCELERATION * Shown when the tape speed is less than ±0.3x. Player/recorder indication When the editing screen display is not shown during swap editing, Counter mode CTL : CTL data TCR : Time code reader data : Time code reader data (when the first field is played back)* TC2 : Time code reader data (when the second field is played back)* TCR• : CTL interpolation mode : LTC data Drop-frame display (NTSC only) TCR 00:00:00·00 Drop frame indication
SUB TC + MODE”, sub time code information is
shown simultaneously on a different line.
setting display on screen.
● Select a menu item by turning the jog dial. For
page 31.
Switch Setting mode. For details, refer to “Hour
meter data display” on page 39.
code is automatically displayed.
For details, refer to “Warnings with Indicators” on
page 145.
is set to “ENABLE(1)”, tape remaining time is
shown in 6 steps.
indication
this indicates which VCR's data is currently displayed on the tape
counter.
P:When the player is selected (SUBTC is not shown)
R:When the recorder or both the recorder and player are selected.
TC1
TCG : Time code generator data
UBR : User bits reader data
UBG : User bits generator data
LTC
In recording or playback in the Drop-frame
mode, the counter display is as shown below.