beautypg.com

Juniper Networks Juniper M-series M10i User Manual

Page 27

background image

One tricolor per port:

Off—Not enabled

Green—Online with no alarms or failures

Amber—Online with alarms for remote failures

Red—Active with a local alarm; router has detected a failure

LEDs

Alarm indication signal (AIS-L, AIS-P)

Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)

Bit interleaved parity errors B1, B2, B3

Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE),
Far-end block error (FEBE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely
errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)

Frame error

Idle code, Idle received

Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)

Out of frame (OOF)

Payload mismatch (PLM-P), payload unequipped (UNEQ-P)

Parity bit (P-bit) disagreements

Path parity error

Remote defect indication (RDI-L, RDI-P)

Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely
errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)

Yellow alarm bit (X-bit) disagreements

Alarms, errors, and
events

Table 7: Optical Interface Support for Channelized OC3 IQ PICs

Single-Mode Intermediate Reach

Optical Parameter

Single-mode transmitter

Optical interface

Telcordia GR-253 compliant

Standard

Single-mode cable: 9.3 miles/15 km

Maximum Distance

1274 through 1356 nm

Wavelength

–15 through –8 dBm

Average launch power

–8 dBm

Receiver saturation

–28 dBm

Receiver sensitivity

Channelized OC3 IQ PIC

27

Channelized OC3 IQ PIC