IBM 6648 User Manual
Page 32

Diagnostic Error Code
FRU/Action
170-197-XXX
Voltage Sensor(s) test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
170-198-XXX
Voltage Sensor(s) test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″ section
170-199-XXX
Voltage Sensor(s) test failed, cause
unknown
1.
Go to the
″Undetermined problems″ section
2.
Flash the system and re-test
3.
Replace component under function test
170-250-XXX
170-251-XXX
Voltage Sensor(s) Voltage limit
error
1.
Power supply
2.
System board
170-254-XXX
Voltage Sensor(s) Voltage
Regulator Module error
1.
Voltage Regulator Module (VRM)
2.
Microprocessor
3.
System board
175-000-XXX
Thermal Sensor(s) Test Passed
1.
No action
175-0XX-XXX
Thermal Sensor(s) failure
1.
Flash system
2.
System board
175-195-XXX
Thermal Sensor(s) Test aborted by
user
1.
Information
2.
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error
threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
175-198-XXX
Thermal Sensor(s) test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to
″Undetermined problems″ section
18
Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649