Diagnostic Error Code
FRU/Action
030-197-XXX
SCSI interface test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
030-198-XXX
SCSI interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″ section
030-199-XXX
SCSI interface test failed, cause
unknown
1.
Go to the
″Undetermined problems″ section
2.
Flash the system and re-test
3.
Replace component under function test
035-000-XXX
RAID interface Test Passed
1.
No action
035-0XX-XXX
RAID interface Failure
1.
RAID signal cable
2.
RAID device
3.
RAID adapter card, if installed
4.
System board
035-195-XXX
RAID interface Test aborted by
user
1.
Information
2.
Re-start the test, if necessary
035-196-XXX
RAID interface test halt, error
threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
035-197-XXX
RAID interface test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
035-198-XXX
RAID interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″ section
035-199-XXX
RAID interface test failed, cause
unknown
1.
Go to the
″Undetermined problems″ section
2.
Flash the system and re-test
3.
Replace component under function test
071-000-XXX
Audio port Interface Test Passed
1.
No action
14
Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649