IBM 6648 User Manual
Page 23

Diagnostic Error Code
FRU/Action
014-013-XXX
014-014-XXX
Parallel port Control
Signal/Loopback test failure
1.
System board
014-015-XXX
Parallel port External Loopback
failure
1.
Wrap plug
2.
System board
014-027-XXX
Parallel port Configuration/Setup
error
1.
Run Setup, enable port
2.
Flash the system
3.
System board
014-03X-XXX
014-04X-XXX
Parallel port failure
1.
System board
014-195-XXX
Parallel port Test aborted by user
1.
Information
2.
Re-start the test, if necessary
014-196-XXX
Parallel port test halt, error
threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
014-197-XXX
Parallel port test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
014-198-XXX
Parallel port test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″ section
014-199-XXX
Parallel port test failed, cause
unknown
1.
Go to the
″Undetermined problems″ section
2.
Flash the system and re-test
3.
Replace component under function test
014-2XX-XXX
014-3XX-XXX
Parallel port failure
1.
External parallel device
2.
System board
015-000-XXX
USB port Interface Test Passed
1.
No action
015-001-XXX
USB port Presence
1.
Remove USB device(s) and re-test
2.
System board
015-002-XXX
USB port Timeout
1.
Remove USB device(s) and re-test
2.
System board
Chapter 1. IBM PC Enhanced Diagnostics error codes
9