IBM 6648 User Manual
Page 172

POST Error Code
FRU/Action
1107
1.
Serial Device Cable
2.
System Board
1110
Register test failed
1.
Run Enhanced Diagnostics
2.
System Board
1116
Interrupt error
1.
Run Enhanced Diagnostics
1117
Failed baud rate test
1.
Run Enhanced Diagnostics
1162
Serial port configuration error
1.
Run Configuration
2.
Serial Adapter
(if installed)
3.
System Board
11XX
Not listed above
1.
System Board
1201
1.
System Board
2.
Any Serial Device
1202, 1206, 1208, 1209, 12XX
1.
Dual Async Adapter/A
2.
System Board
3.
Any Serial Device
1207
1.
Communications Cable
2.
Dual Async Adapter/A
13XX
1.
Game Adapter
1402
Printer not ready
Information only
1403
No paper error, or interrupt failure
Information only
1404
System board timeout failure
1.
Run Enhanced Diagnostics
1405
Parallel adapter error
1.
Run Enhanced Diagnostics
1406
Presence test error
1.
Run Enhanced Diagnostics
14XX
Not listed above. Check printer before
replacing system board
1.
Printer
2.
System Board
15XX
1.
SDLC Adapter
1692
Boot sequence error
1.
Run FDISK to ensure at least one active
partition is set active
16XX
1.
36/38 Workstation Adapter
1762
Hard disk drive configuration error
1.
Run Configuration. (See “Setup Utility
program” on page 122.)
158
Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649