IBM 6648 User Manual
Page 27

Diagnostic Error Code
FRU/Action
025-197-XXX
IDE interface test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
025-198-XXX
IDE interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″ section
025-199-XXX
IDE interface test failed, cause
unknown
1.
Go to the
″Undetermined problems″ section
2.
Flash the system and re-test
3.
Replace component under function test
030-000-XXX
SCSI interface Test Passed
1.
No action
030-00X-XXX
030-01X-XXX
SCSI interface failure
1.
SCSI signal cable
2.
Check power supply
3.
SCSI device
4.
SCSI adapter card, if installed
5.
System board
030-027-XXX
SCSI interface
Configuration/Setup error
1.
SCSI signal cable
2.
Flash the system
3.
SCSI device
4.
SCSI adapter card, if installed
5.
System board
030-03X-XXX
030-04X-XXX
SCSI interface error
1.
SCSI signal cable
2.
Check power supply
3.
SCSI device
4.
SCSI adapter card, if installed
5.
installed System board
030-195-XXX
SCSI interface Test aborted by
user
1.
Information
2.
Re-start the test, if necessary
030-196-XXX
SCSI interface test halt, error
threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
Chapter 1. IBM PC Enhanced Diagnostics error codes