5100 Memory Controller Hub Chipset for Communications, Embedded, and Storage Applications

July 2008

TDG

Order Number: 318676-003US

15

Intel

®

5100 MCH Chipset

Table 4

summarizes the thermal budget required to adequately cool the Intel

®

5100

MCH Chipset in one configuration using a TDP of 25 W. Further calculations would need

to be performed for different TDPs. Because the results are based on air data at sea

level, a correction factor would be required to estimate the thermal performance at

other altitudes.

5.0

Thermal Metrology

The system designer must make temperature measurements to accurately determine

the thermal performance of the system. Intel has established guidelines for proper

techniques to measure the MCH case temperatures.

Section 5.1

provides guidelines on

how to accurately measure the MCH case temperatures.

Section 5.2

contains

information on running an application program that will emulate anticipated maximum

thermal design power (

Figure 6

).

5.1

MCH Case Measurement

The Intel

®

5100 MCH Chipset cooling performance is determined by measuring the

case temperature using a thermocouple. For case temperature measurements, the

attached method outlined in this section is recommended for mounting a

thermocouple.

Special care is required when measuring the case temperature (T

C

) to ensure an

accurate temperature measurement. Thermocouples are often used to measure T

C

.

When measuring the temperature of a surface that is at a different temperature from

the surrounding local ambient air, errors may be introduced in the measurements. The

measurement errors can be caused by poor thermal contact between the thermocouple

junction and the surface of the integrated heat spreader, heat loss by radiation,

convection, by conduction through thermocouple leads, or by contact between the

thermocouple cement and the heatsink base. To minimize these measurement errors,

the approach outlined in the next section is recommended.

Note:

The thermocouple attach example shown below is on a different package, but the

method and groove dimensions are the same. The thermocouple bead needs to be

centered on the IHS.

5.1.1

Supporting Test Equipment

To apply the reference thermocouple attach procedure, it is recommended that you use

the equipment (or equivalent) given in

Table 5

.

Table 4.

Required Heatsink Thermal Performance (Ψ

CA

)

Device

Ψ

CA

(°C/W) at T

LA

= 45 °C

Ψ

CA

(°C/W) at T

LA

= 60 °C

Intel

®

5100 MCH Chipset @ 25 W

2.4

1.8