Diagnostic Messages

Result

Test Specific String

Failed

Test setup error: Invalid microprocessor in socket number U2 or BIOS setup
problem.

Action:

1. Update the BIOS. See the “Getting Help Information” section of this

Server

Library for information about obtaining updates.

2. If the problem persists, replace the primary microprocessor and run the

microprocessor diagnostic program again.

If the problem persists, have the system serviced.

Failed

Test setup error: Invalid microprocessor in socket number U21 or BIOS setup
problem.

Action:

1. Update the BIOS. See the “Getting Help Information” section of this

Server

Library for information about obtaining updates.

2. If the problem persists, replace the secondary microprocessor and run the

microprocessor diagnostic program again.

If the problem persists, have the system serviced.

Warning

Test setup error: Secondary microprocessor not installed or BIOS setup problem.

Action:

1. Verify that the secondary microprocessor is installed and seated correctly.

2. If the problem persists, update the BIOS. See the “Getting Help Information”

section of this

Server Library for information about obtaining updates.

3. If the problem persists, replace the secondary microprocessor and run the

microprocessor diagnostic program again.

If the problem persists, have the system serviced.

Function: System Memory Messages (201)

Result

Test Specific String

Failed

Test setup error: Corrupt DMI BIOS, information in BIOS is not as expected.

Action: Update the BIOS. See the “Getting Help Information” section of this
Server Library for information about obtaining updates.

If the problem persists, have the system serviced.

Failed

Test setup error: Unknown hardware problem associated with microprocessor in
socket number U5.

Action:

1. Update the BIOS and run the diagnostic program again. See the “Getting Help

Information” section of this

Server Library for information about obtaining

updates.

2. If the problem persists, replace the primary microprocessor.

If the problem persists, have the system serviced.

Failed

Test setup error: Unknown hardware problem associated with microprocessor in
socket number U6.

Action:

1. Update the BIOS and run the diagnostic program again. See the “Getting Help

Information” section of this

Server Library for information about obtaining

updates.

2. If the problem persists, replace the secondary microprocessor.

If the problem persists, have the system serviced.

132

Netfinity 5000 Server Hardware Information and Procedures