Function: thermal system messages (175), Function: status display messages (180), Diagnostic messages – IBM 5000 User Manual
Page 136

Diagnostic Messages
Function: System-Management Processor Messages (165)
Result
Test Specific String
Failed
System-management processor on system board.
Action: Have the system serviced.
Function: Thermal System Messages (175)
Function
Test Specific String
Failed
Fan #1
Note: The FAN1 LED on the system board will also be on.
Action: Replace fan 1.
If the problem persists, have the system serviced.
Failed
Fan #2
Note: The FAN2 LED on the system board will also be on.
Action: Replace fan 2.
If the problem persists, have the system serviced.
Failed
Temperature sensed on system board is out of range.
Action: If one of the FAN LEDs on the system board is on, replace the indicated
fan.
If the problem persists, have the system serviced.
Function: Status Display Messages (180)
Result
Test Specific String
Failed
Information LED panel.
Action: Have the system serviced.
Failed
Diagnostics LED panel.
Action: Have the system serviced.
Failed
LED on system board.
Action: Have the system serviced.
Failed
LED on hot-swap SCSI backplane.
Action: Have the system serviced.
Function: System Memory Messages (201)
Result
Test Specific String
Failed
x MB DIMM location J22
Note:
x is the size in megabytes of the DIMM.
Action:
1. Reseat the DIMM in DIMM socket J22.
2. If the problem persists, replace the DIMM.
If the problem persists, have the system serviced.
Failed
x MB DIMM location J17
Note:
x is the size in megabytes of the DIMM.
Action:
1. Reseat the DIMM in DIMM socket J17.
2. If the problem persists, replace the DIMM.
If the problem persists, have the system serviced.
128
Netfinity 5000 Server Hardware Information and Procedures