Function: thermal system messages (175), Function: status display messages (180), Diagnostic messages – IBM 5000 User Manual

Page 136

background image

Diagnostic Messages

Function: System-Management Processor Messages (165)

Result

Test Specific String

Failed

System-management processor on system board.

Action: Have the system serviced.

Function: Thermal System Messages (175)

Function

Test Specific String

Failed

Fan #1

Note: The FAN1 LED on the system board will also be on.

Action: Replace fan 1.

If the problem persists, have the system serviced.

Failed

Fan #2

Note: The FAN2 LED on the system board will also be on.

Action: Replace fan 2.

If the problem persists, have the system serviced.

Failed

Temperature sensed on system board is out of range.

Action: If one of the FAN LEDs on the system board is on, replace the indicated
fan.

If the problem persists, have the system serviced.

Function: Status Display Messages (180)

Result

Test Specific String

Failed

Information LED panel.

Action: Have the system serviced.

Failed

Diagnostics LED panel.

Action: Have the system serviced.

Failed

LED on system board.

Action: Have the system serviced.

Failed

LED on hot-swap SCSI backplane.

Action: Have the system serviced.

Function: System Memory Messages (201)

Result

Test Specific String

Failed

x MB DIMM location J22

Note:

x is the size in megabytes of the DIMM.

Action:

1. Reseat the DIMM in DIMM socket J22.
2. If the problem persists, replace the DIMM.

If the problem persists, have the system serviced.

Failed

x MB DIMM location J17

Note:

x is the size in megabytes of the DIMM.

Action:

1. Reseat the DIMM in DIMM socket J17.
2. If the problem persists, replace the DIMM.

If the problem persists, have the system serviced.

128

Netfinity 5000 Server Hardware Information and Procedures