Diagnostic Messages

Result

Test Specific String

Failed

Test setup error: Corrupt BIOS in ROM.

Action: Update the BIOS. See the “Getting Help Information” section of this
Server Library for information about obtaining updates.

If the problem persists, have the system serviced.

Function: System Cache Messages (202)

Result

Test Specific String

Failed

Test setup error: No L2 cache detected on microprocessor socket U2 or BIOS setup
problem.

Action:

1. Update the BIOS and run the diagnostic program again. See the “Getting Help

Information” section of this

Server Library for information about obtaining

updates.

2. If the problem persists, replace the primary microprocessor.

If the problem persists, have the system serviced.

Failed

Test setup error: No L2 cache detected on microprocessor socket U21 or BIOS
setup problem.

Action:

1. Update the BIOS and run the diagnostic program again. See the “Getting Help

Information” section of this

Server Library for information about obtaining

updates.

2. If the problem persists, replace the secondary microprocessor.

If the problem persists, have the system serviced.

Warning

Test setup error: Cache is disabled. Use system setup to enable before retrying the
test.

Action: Use the Cache Control selection in the Advanced Setup menu of the
Configuration/Setup Utility to enable the cache. (See “Advanced Setup” on
page 28.)

If the problem persists, have the system serviced.

Failed

Test setup error: Corrupt DMI BIOS. Information in BIOS is not as expected.

Action: Update the BIOS. See the “Getting Help Information” section of this
Server Library for information about obtaining updates.

If the problem persists, have the system serviced.

Failed

Test setup error: BIOS cannot access VPD information.

Action: Update the BIOS. See the “Getting Help Information” section of this
Server Library for information about obtaining updates.

If the problem persists, have the system serviced.

Failed

Test setup error: Unknown hardware problem associated with microprocessor in
socket number U2.

Action:

1. Update the BIOS. See the “Getting Help Information” section of this

Server

Library for information about obtaining updates.

2. If the problem persists, replace the primary microprocessor and run the

diagnostic program again.

If the problem persists, have the system serviced.

Chapter 6. Solving Problems