Table 11. Netfinity 5000 Server Operating Specifications

Size

– Depth: 560 mm (22.05 in.)

– Height: 230 mm (9.06 in.)

– Width: 420 mm (16.54 in.)

Weight

Typical server as shipped: 39 kg
(85.8 lb)

Environment

Air temperature:

– Server on: 10° to 35° C

(50° to 95° F)
Altitude: 0 to 914 m (3000 ft.)

– Server on: 10° to 32° C

(50° to 90° F)
Altitude: 914 m (3000 ft.) to
2133 m (7000 ft.)

– Server off: 10° to 43° C

(50° to 110° F)
Maximum Altitude: 2133 m
(7000 ft.)

Humidity:

– Server on: 8% to 80%

– Server off: 8% to 80%

Maximum altitude: 2133 m
(7000 ft)

Electrical Input

Sine-wave input (50 to 60 Hz) is
required

Input voltage:

– Low range:

- Minimum:

90 V ac

- Maximum: 137 V ac

– High range:

- Minimum: 180 V ac

- Maximum: 265 V ac

– Input kilovolt-amperes (kVA)

approximately:

- Minimum configuration as

shipped: 0.08 kVA

- Maximum configuration:

0.52 kVA

Total Power Available for Drives

Nominal Operating Current allowed:

– +5 V dc line: 5.3 A

– +12 V dc line: 5.0 A

Heat Output

Approximate heat output in British
Thermal Units (Btu) per hour:

– Minimum configuration:

350 Btu (102 watts)

– Maximum configuration:

860 Btu (251 watts)

Acoustical Noise Emissions Values

Sound power, idling

– 6.2 bel for open bay system

(no hard disk drives installed)

– 6.3 bel for system with one

hard disk drive installed)

Sound power, operating

– 6.2 bel for open bay system

(no hard disk drives installed)

– 6.3 bel for system with one

hard disk drive installed)

Sound pressure, idling

– 47 dBa for open bay system

(no hard disk drives installed)

– 48 dBa for system with one

hard disk drive installed)

Sound pressure, operating

– 47 dBa for open bay system

(no hard disk drives installed)

– 48 dBa for system with one

hard disk drive installed)