beautypg.com

Mitsubishi motor drives, Woods motor drives, Yaskawa motor drives – ICP DAS USA DB25 User Manual

Page 65

background image

Application Notes – Motor Drives

M

ITSUBISHI

M

OTOR

D

RIVES


Drive Specific Completion Codes
(Bits 6 thru 4 of Result Word)

2 = Drive Returned a Mode Error
3 = Drive Returned an Instruction Code Error
4 = Drive Returned a Data Range Error
5 = Drive Returned a Communications Error or DN-3000 encountered a Communications Error.
6 = Drive Returned an Error Code other than those designated above

W

OODS

M

OTOR

D

RIVES


Drive Specific Completion Codes
(Bits 6 thru 4 of Result Word)

5 = The DN-3000 encountered a communications error when receiving the response from the drive.

Configuring A Woods Drive For Serial Communications

1) Parameter number 21 must be set to the value of 16, 17, or 18 and parameter number 22 must be set to

the value of 3 to be able to control the drive (inverter) with the Woods SIO option.

2) Any parameter may be read from the drive (inverter) at any time during operation.

3) Parameter numbers that are less than 30 with the exception of 21 may be written any time during

operation.

4) Parameter numbers 30 and above can only be written while the drive (inverter) is in the program

mode. To place the drive into the program mode, when the motor is stopped, write the value of 4 to
parameter number 22. When all desired parameters have been changed, the drive should be taken out
of the program mode by writing the value of 3 to parameter number 22.


Y

ASKAWA

M

OTOR

D

RIVES


“G5” Drive Specific Completion Codes
(Bits 6 thru 4 of Result Word)

5 = The DN-3000 encountered a communications error when receiving the response from the drive

(Inverter).


59

This manual is related to the following products: