DeviceNet to PLCs or Devices
18
O
UTPUT
D
ATA
T
ABLE
Within the “I/O Data Configuration” screen, use the DOWN arrow key to move the focus to the Output
Data button and press the ENTER key. This action opens the Output Data Table setup screen to allow
you to set up the PLC/Device registers to be mapped to each word of Output data.
Output data is data received by the DN-3000 from the DeviceNet Host to be written to PLC/Device
registers. Each word of Output data (except those reserved for the Command Block) can be mapped to
specific PLC/Device registers. Output data is only written to registers when that data changes.
Use the UP/DOWN arrow keys to scroll through the list of Output data words until the highlight bar is
over the Output word you wish to edit, and press ENTER. A window will open allowing you to edit the
PLC/Device Address, File Number (Allen-Bradley PLCs only) and Register Number mapped to that
Output word.