beautypg.com

Protective devices – Multiquip 20 KW Standby Generator MQP20P User Manual

Page 30

background image

page 30 —MQp20p STaNDBY geNeRaTOR • OpeRaTiON aND paRTS MaNual — Rev. #1 (11/28/11)

PrOtECtIvE DEvICES

pROTeCTive DeviCeS

Protection devices and emergency stop devices are

provided for protection of the generator against trouble

during operation. The alarm LED on the digital controller

lights or flashes when a fault is detected.
When a major fault is detected, such as low oil pressure,

high water temperature, and overspeed, the engine

automatically shuts down. Check the display for the fault

and correct the problem.
For minor faults, the engine will continue working. Stop the

engine and remedy the cause of the problem.
Before inspecting or troubleshooting the generator, press

the

OFF button on the Digital Controller. Place all circuit

breakers in the

OFF position and allow sufficient time for

adequate cooling.

After automatic shutdown, always inspect the generator

and eliminate any problems that might have caused the

shutdown before attempting to restart the generator.
When ready to restart the generator, make sure all circuit

breakers are

OFF. Also check and make sure that the OFF

button on the Digital Controller has been pressed to clear

the system and that the OFF LED on the Digital Controller

is

ReD. Restart the generator as outlined in the Startup

section of this manual.
Refer to the MEC20 Microprocessor Engine/Generator

Controller Manual for detailed information of faults and

display information.

This manual is related to the following products: