Hbdv7 series direct vent gas fireplace, Clearances clearances to combustibles w arning, Mantel clearances – Monessen Hearth HBDV400N/PSC7 User Manual

Page 8: Warning

background image

HBDV7 Series Direct Vent Gas Fireplace

8

54D8000

CleARANCeS

CleARANCeS to CoMBuStIBleS

W

ARNING

Follow these instructions carefully to ensure safe installation. Failure
to follow instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other combustible
material other than wood flooring. If installed on carpet or vinyl flooring,
the appliance shall be installed on a metal, wood or noncombustible
material panel extending full width and depth of the appliance.

71” 

Minimum

12” 

Minimum

12” 
Max.

Min. 4” 
From Either 
Side Wall

FP2580
mantel clearances

Figure 4 -
Clearances

Ceiling

Combustible Mantel

12”

12”

FP2581
mantel clearances

Wall

Stud

Standoff

FP581

Top of Exhaust
Louvers

Side View

1"

256O”

3"

4"

156O”

256O”

45°

FP2582
mantel side clearance

Wall

Combustible
Material Area

Side of Fire-
place Opening

FP58

top View

Figure 5 -
Mantel Clearances

MANtel CleARANCeS

Note: The combustible area above the facing must not protrude
more than 3/4" from the facing. If it does, it is considered a mantel
and must meet the mantel requirements listed in this manual.

W

ARNING

Never obstruct or modify the air inlet or
outlet grilles (louvers). this may create a
fire hazard.

FP580

Note: All mantel shelves, regard-
less of depth, should be a mini-
mum of 1” from top of fireplace.
Mantel shelf shall not exceed 1”
maximum depth at 1” minimum
height from opening.

Insulation
Board