HBDV7 Series Direct Vent Gas Fireplace

54D8000

35

oPtIoNAl FAN BloWeR SySteMS

Blot AutoMAtIC tHeRMoStAt BloWeR

Figure 56 -
BLOT Blower Wiring Diagram

BLACK

BLACK

WHITE

GREEN

BLACK

BLACK

WHITE

Receptacle 

Junction 

Box

120VAC

Speed Control 

FP2675
BLOT blower wiring

FP675

Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing the
fireplace. Wire with minimum 60° C wire in accordance
with prevailing codes.

FK-12 MANuAl BloWeR

1. This must be done before framing the fireplace. When

installing the FK-1 blower, a wall switch control must
be installed to control the blower.

. The fireplace power supply is wired through the blower

wall switch and then brought to the fireplace junction
box.

3. The jumper clip on the plug receptacle must be re-

moved. Figure 57. Use needlenose pliers to break off
the jumper clip.

Junction Box

Blower

Wall Switch

Black (live)

Green (ground)

White (neutral)

Red

Black

FK-12 Blower

Plug into switch outlet

FP2676
FK12 wiring

Jumper clip on plug
receptacle must be
removed on power side to
make outlet switchable

Figure 57 -
FK-12 Blower wiring Diagram

FP676