4-13

SECTION 4

MAINTENANCE

II. MAINTENANCE - EVERY 3 MONTHS

WARNING:

All electric power must be shut

off

before beginning this maintenance procedure.

NOTE: It is recommended that an authorized Middleby
Marshall service agent should perform the 3-month and
6-month maintenance procedures.

A. Cleaning the blower motors (See Figure 4-23.)

Remove the end panels from the machinery compart-
ment. Clean the blower motors in each oven section and
the surrounding area, using either compressed air or
CO

2

.

Thoroughly blow out the motor compartment and

vents inside the motor. Failure to do this may cause
premature failure of the electric motor.

Blow out
this area

Figure 4-24. Electrical Terminal

Maintenance

Figure 4-23. Blower Motor

Cleaning

B. Electrical terminals

Open the control panel door by loosening the two screws.
Tighten all electrical control terminal screws, including
the electrical contactor terminal screws, as shown in
Figure 4-24.