2-2

SECTION 2

INSTALLATION

2"

51mm

Minimum

18"

458mm

18"

458mm

12"

305mm

3”

76mm

II. INSTALLATION, PREPARATION, AND

SUPPLY

When preparing the oven for installation at a location, the latest

International, National or Local Requirements should be

adhered to.

The ovens must be installed on an even (level) non-flammable

flooring and any adjacent walls must be non-flammable. The

minimum allowed distance from the rear of the oven to the wall

is 12” (30cm).

The ovens can be supported only by legs. No casters are

allowed. It should be made certain that there are no obstructions

located around or underneath the oven that interfere with air

circulation.

The ovens must be installed under a ventilating hood with

electrical exhaust air sensing control.

The gas supply connection should be according to applicable

ISO-228-1 or ISO-7-1 recommendations.

Normally, the oven is preparted and adjusted to the specific

gas type used by the customer. Before operating the oven,

check the label on the oven and also on the packaging that the

gas type indicated matches the local supply at the installation.

If not, refer to Section VI, PREPARATION FOR VARIOUS

GASES, in this chapter and convert as directed.

All installations, conversions and service work must be

performed by an Authorized Service Agent according to the

instructions supplied by the manufacturer.

When converting from one gas type to a different type, the

orifices supplied with the conversion kit must be checked for

proper size as specified in this manual to assure that the oven

is operating at the nominal rated input.