beautypg.com

Vii. gas supply for gas heated ovens, Caution – Middleby Cooking Systems Group PS360/PS360WB User Manual

Page 39

background image

2-25

SECTION 2

INSTALLATION

Figure 2-35

Flexible Hose Connector Installation

Appliance

Connection/

Male Nipple

Flexible Hose

Correct Position

Full-Flow Gas

Shutoff Valve

To Gas

Supply Pipe

90° ST

Elbow

Union

VII. GAS SUPPLY FOR GAS HEATED OVENS

Pipe sizing -- Always install a shut off valve in the gas supply

line to the oven. This valve should be the same size as the

supply line.
Please remember that the longer the pipe runs, the more the

pressure drops. One 90° elbow equals a 1,2 m length of pipe.
Each oven section requires a nominal gas input as follows:

PS360U,L (per oven)

40 kW

PS360WB-U, -L (per oven)

50 kW

Follow the recommended pipe sizing and meter sizing as

indicated in the Rough-in Drawing (Figure 2-31,Page 2-22).
The flexible hose furnished with the oven must be positioned

as shown in Figure 2-35.
NOTE: The recommended pipe sizes are larger than usually

required to eliminate any operation problems. It is much less

expensive to make the initial installation large enough to do the

job rather than redoing the job later.
For lighting instructions, refer to Step-by-Step Operation in the

OPERATION Section of this manual.

CAUTION

DURING PRESSURE TESTING NOTE ONE OF THE

FOLLOWING:
1. The oven and its individual shutoff valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressure in

excess of 1/2 psig (3.45 kPA).
2. The oven must be isolated from the gas supply piping

system by closing its individual manual shutoff valve

during any pressure testing of the gas supply piping

system at test pressure equal to or less than 1/2 psig (3.45

kPA).
3. If the incoming pressure is over 50 mbars, a separate

regulator must be installed before the 3/4” manual gas

shutoff valve located at the rear outside of the oven.

WARNING:

To prevent damage to control

valve regulator during initial

turn on of gas, it is very

important to open manual

shutoff valve very slowly.

After the initial gas turn on, the

manual shutoff valve must

remain open except during

pressure testing as outlined in

the above steps or when

necessary during service

maintenance.