IMPORTANT SAFETY INFORMATION

Continued from page 3

16. Keep room area clear and free from combustible materi-

als, gasoline and other flammable vapors and liquids.

17. Unvented gas heaters are a supplemental zone heater.

They are not intended to be the primary heating appli-

ance.

18. Unvented gas heaters emit moisture into the living area.

In most homes of average construction, this does not pose

a problem. In houses of extremely tight construction,

additional mechanical ventilation is recommended.

19. During manufacturing, fabricating and shipping, various

components of this appliance are treated with certain

oils, films or bonding agents. These chemicals are not

harmful but may produce annoying smoke and smells

as they are burned off during the initial operation

of the appliance; possibly causing headaches or eye

or lung irritation. This is a normal and temporary

occurrence.

The initial break-in operation should last two to three

hours with the burner at the highest setting. Provide

maximum ventilation by opening windows or doors to

allow odors to dissipate. Any odors remaining after this

initial break-in period will be slight and will disappear

with continued use.

20. Input ratings are shown in BTU per hour and are for

elevations up to 2,000 feet. For elevations above 2,000

feet, input ratings should be reduced 4 percent for

each 1,000 feet above sea level. Refer to the National

Fuel Gas Code.

21. The appliance and its appliance main gas valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in

excess of 1/2 psig (3.5 kPa).

22. The appliance must be isolated from the gas supply

piping system by closing its equipment shutoff valve

during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2 psig

(3.5 kPa).

23. Do not use this room heater if any part has been under

water. Immediately call a qualified service technician

to inspect the room heater and to replace any part of the

control system and any gas control which has been under

water.

24. This appliance must not be used with glass doors in the

closed position. This can lead to pilot outages and severe

sooting outside the fireplace.

25. Never burn solid fuels in a fireplace where a unvented

room heater is installed.

26. Always have a fireplace screen in place when the appli-

ance is in operation and, unless other provisions for

combustion air are provided, the screen must have an

opening(s) for induction of combustion air.

Never connect unit to private
(non-utility) gas wells. This
gas is commonly known as
wellhead gas.

W

ARNING

www.nficertified.org

We suggest that our gas hearth
products be installed and
serviced by professionals who
are certified in the U.S. by the
National Fireplace Institute

®

(NFI) as Gas Specialists.