beautypg.com

Checking the burner flame – Monessen Hearth HVFL18 User Manual

Page 31

background image

59D1015

31

In normal operation at full rate after 15 minutes, the following flame appearances should be observed:

Figure 42 - Correct Appearance of Rear Flames

of Kentucky Stack

The left and right rear flames should be yellow and extend 1"-2" above the mid log top surfaces. The yellow flames should

not

contact the logs. There should be glowing embers on the front burner. Note: The front flames and embers will be

an opaque orange color during the burn off time.

OPERATING INSTRUCTIONS

Avoid any drafts that alter burner flame patterns.

Do not allow fans to blow directly into the fireplace. Do

not place a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting

and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils,

films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are

burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is

a normal and temporary occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum

ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will

be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting

outside the fireplace. See Figure 3, page 11.

CHECKING THE BURNER FLAME

Figure 43 - Correct Appearance of Rear Flames

of Split Maple