beautypg.com

Manual control lighting instructions – Monessen Hearth HVFL18 User Manual

Page 33

background image

59D1015

33

Push

Push

Rotate

Rotate

Rotate

OPERATING INSTRUCTIONS

Figure 45 - IGN Position

Figure 46 - HIGH Position

Figure 47 - LOW Position

1. STOP! Read the safety information.

2. Make sure the manual shutoff valve is fully open.

3. This heater is equipped with an ignition device (piezo) which automatically lights the pilot.

4. See Figure 44, page 32 for the location of the piezo ignitor and control knob. Push in gas control knob

slightly and turn control knob clockwise

to the OFF position.

NOTE:

Knob cannot be turned to OFF unless knob is pushed in slightly. Do not force.

5. Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP!

Follow the instructions under What To Do if You Smell Gas, page 32. If you do not smell gas, go to the

next step.

6. From OFF position, push in gas control knob slightly and turn counterclockwise

to the IGN

position. See Figure 45. Push in and hold control knob for 5 seconds.

NOTE:

If you are running the heater for the first time, it will be necessary to press in the control knob

for 30 seconds to allow air to bleed out of the gas piping.

7. With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The

pilot is located on the left side of the heater, behind the middle log and on the back of the rear burner. If

piezo ignitor does not light the pilot, refer to Match Lighting Instructions, page 35.

8. Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the

gas while the thermocouple is warming up.

9. Release the control knob.

• If the knob does not pop out when released, stop and immediately call your service technician

or gas supplier.

• If the ODS pilot will not stay lit after several tries, push and turn the gas control knob clockwise

to OFF and wait 15 seconds. Repeat steps 6 through 9.

10. Push in control knob and turn counterclockwise

to the HIGH setting. At this location the

control knob will pop out when positioned correctly. The knob can now be positioned at any position

between HIGH and LOW. Refer to Figures 46 and 47.

MANUAL CONTROL LIGHTING INSTRUCTIONS

W

ARNING

TO TURN OFF GAS TO HEATER

1. Turn control knob clockwise

to OFF position to completely shut off the heater.

2. If applicable: Turn off all electric power to the heater.

Wait 30 seconds before readjusting the
heater when the control knob has been
turned down to a lower setting.

W

ARNING