beautypg.com

Floor clearance – Monessen Hearth HVFL18 User Manual

Page 17

background image

59D1015

17

Heater in
Fireplace or
Firebox

1

3

/

8

" Minimum

Combustible

Material

14" Minimum

Heater in
Fireplace or
Firebox

Combustible

Material

This Distance
May Now Be
Less than 5"

FLOOR CLEARANCE

The gas log heater must be installed at least 5" above any combustible flooring material, such as carpeting or tile,

which is closer than 14" to the base of the fireplace. The minimum distance must be maintained from the top surface

of carpeting, tile, etc. See Figure 11.

OR,

The gas log heater may be installed nearer to the floor if a minimum of 14" of noncombustible material such as slate or

marble is installed between the base of the fireplace and the combustible flooring. See Figure 12.

Figure 11 - Minimum Clearance above Combustible Flooring

Figure 12 - Minimum Clearance above Combustible Flooring with

Noncombustible Material Installed at Base of Fireplace