Troubleshooting the MVME240x

Solving Startup Problems

In the event of difficulty with your MVME240x VME Processor Module,
try the simple troubleshooting steps on the following pages before calling
for help or sending the board back for repair. Some of the procedures will
return the board to the factory debugger environment. (The board was
tested under these conditions before it left the factory.) The selftests may
not run in all user-customized environments.

Table D-1. Troubleshooting MVME240x Modules

Condition

Possible Problem

Try This:

I. Nothing works, no

display on the
terminal.

A. If the

CPU

LED is

not lit, the board
may not be getting
correct power.

1. Make sure the system is plugged in.

2. Check that the board is securely installed in its backplane or

chassis.

3. Check that all necessary cables are connected to the board, per

this manual.

4. Check for compliance with Installation Considerations, per this

manual.

5. Review the Installation and Startup procedures, per this manual.

They include a step-by-step powerup routine. Try it.

B. If the LEDs are lit,

the board may be
in the wrong slot.

1. The VME processor module should be in the first (leftmost) slot.

2. Also check that the “system controller” function on the board is

enabled, per this manual.

C. The “system

console” terminal
may be configured
incorrectly.

Configure the system console terminal per this manual.